2.4.5 Minimum Parameters Required and Input Signals cont.

50

• For position control

Cn-02 bits 3, 4 and 5

Reference pulse form selection (see page 70)

Cn-24

Electronic gear ratio (numerator) (see page 81)

Cn-25

Electronic gear ratio (denominator) (see page 81)

When these parameters (except for Cn-03) are changed, always turn the power OFF,
then back ON. This makes the new setting valid.

If the specified direction of rotation differs from the actual direction of rotation, the wiring
may be incorrect. In this case, recheck the wiring and correct it accordingly. Then, if the
direction of rotation is to be reversed, set the following parameter:

Cn-02 (bit 0)

Reverse rotation mode (see page 54)

After changing the Cn-02 setting, always turn the power OFF, then ON, to make the new
setting valid.

J

Input Signals

The following table lists the minimum input signals required to conduct a test run. For de-
tails of each input signal, refer to the relevant page.

Signal Name

Pin

Number

Function

/S-ON

(servo ON)

1CN-40

Switching between motor ON and OFF status. The

memory switch can be used to eliminate the need for

external short-circuit wiring (see page 131).

P-OT

(forward

rotation

prohibited)

1CN-42

Overtravel limit switch

The memory switch can be used to eliminate the

N-OT

(reverse

rotation

prohibited)

1CN-43

The memory switch can be used to eliminate the

need for external short-circuit wiring (see page 56).