5.5 Selecting Peripheral Devices

423

Select plug, Back

Shell or End Bell, and

cable clamp

according to the

motor type.

Select plug

according to the

motor type.

A

Operation environment requiring Enclosure IP67-based

The standard specification for SGMG, SGMS and

SGMD Types is Enclosure IP67.

The shaft needs an oil seal. The motor and en-

coder connectors must also be based on IP67.

Note

For G Series 1500 min

−1

type

(5.5 kW or more) and G Series
1000 min

−1

type (4.4 kW or

more), add a brake connector.

Any brake?

Flexible

conduit

is used?

Encoder

Select plug, Back Shell

(straight or L-shaped)

and cable clamp.

Select plug only.

MS3106A20-29S (D190)

Flexible conduit

is used?

Flexible conduit

is used?

No

Yes

Select plug, Back

Shell or End Bell, and

cable clamp

according to the

motor type.

Select plug

according to the

motor type.

Cannot be selected

Can be selected

Can be selected

Cannot be selected

Separately purchase

plugs for brake.

Items for brake

can be selected.

SGMG-55AjA

-75AjA
-1AAjA
-1EAjA
-44AjB
-60AjB

Connectors for brake

are also required.

to (b)

Note

1. Power cable and flexible conduit must be prepared by the customer.
2. The customer must purchase an appropriate encoder cable according to the encoder type

(incremental or absolute encoder) and an encoder connector kit (for the SERVOPACK end), and assemble them.

3.

After selecting a brake power supply unit and a battery for the absolute encoder, proceed to (b) on page 421.

With oil seal

Yes

No

No

Yes

No

Yes

Only these five types

can be selected.

5

Advertising