Input clr 1cn-15, Input /clr 1cn-14 – Yaskawa SGDB User Manual

Page 84

Advertising
background image

APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.2 Inputting Position Reference

72

Allowable Voltage Level and Timing for Reference Pulse Input

Reference Pulse Form

Electrical Specifications

Remarks

Sign + pulse train input

(SIGN + PULS signal)
Maximum reference

frequency: 450 kpps

¨

reference

©

reference

The signs for each

reference pulse are as

follows:

¨

: High level

©

: Low level

90° different two-phase

pulse train

(phase A + phase B)
Maximum reference

frequency

x 1 multiplier:

450 kpps

x 2 multiplier:

400 kpps

x 4 multiplier:

200 kpps

Phase A

Phase B

Phase B is 90°

forward from phase B

Phase B is 90°

behind phase B

Parameter Cn-02 (bits 3,

4 and 5) is used to

switch the input pulse

multiplier mode.

CCW pulse + CW pulse
Maximum reference

frequency: 450 kpps

CCW pulse

CW pulse

¨

reference

©

reference

J

Cleaning the Error Counter

The following describes how to clear the error counter.

Input CLR 1CN-15

Error Counter Clear Input

For Position

Control Only

Input /CLR 1CN-14

Error Counter Clear Input

For Position

Control Only

Setting the CLR signal to high level does the fol-
lowing:

• Sets the error counter inside the SERVOPACK

to 0.

• Prohibits position loop control.

Use this signal to clear the error counter from the
host controller.

Bit A of memory switch Cn-02 can be set so that the error counter is cleared only once
when the leading edge of an input pulse rises.

3

SGDB SERVOPACK

Clear

Position loop

error counter

Advertising