Inspection and Maintenance

This section describes the basic inspections and maintenance for Σ-Series servo drives.

6.1.1 Servomotor

For inspection and maintenance of servomotors, follow the simple, daily inspection proce-
dures in the table below.

The AC servomotors are brushless. Simple, daily inspection is sufficient. The inspection and
maintenance frequencies in the table are only guidelines. Increase or decrease the frequen-
cy to suit the operating conditions and environment.

Item

Frequency

Procedure

Comments

Vibration and

noise

Daily

Touch and listen.

Levels higher than normal?

Appearance

According to

degree of

contamination

Clean with cloth or

compressed air.

Insulation

resistance

measurement

At least once a

year

Disconnect SERVOPACK

and test insulation resistance

at 500 V. Must exceed 10

MΩ. (See note below)

Contact your Yaskawa

representative if the

insulation resistance is

below 10 MΩ.

Replace oil seal At least once

every 5,000

hours

Remove servomotor from

machine and replace oil seal.

Applies only to motors with

oil seal.

Overhaul

At least once

every 20,000

hours or 5 years

Contact your Yaskawa

representative.

The customer should not

disassemble and clean the

servomotor.

Note

Measure across the servomotor FG and the phase-U, phase-V, or phase-W pow-
er lead.

During inspection and maintenance, do not disassemble the servomotor.
If disassembly of the servomotor is required, contact your Yaskawa representative.