USING THE DIGITAL OPERATOR

4.1.5 Operation in Status Display Modecont.

184

Bit Data

Description

Control Power ON

Lit when SERVOPACK control power ON. Not lit when

SERVOPACK control power OFF.

Base Block

Lit for base block. Not lit at servo ON.

Positioning Complete

Lit if error between position reference and actual motor

position is below preset value.

Not lit if error between position reference and actual

motor position exceeds preset value.

Preset value: Set in Cn-1B (1 pulse is standard setting)

TGON

Lit if motor speed exceeds preset value.

Not lit if motor speed is below preset value.

Preset value: Set in Cn-0B (20 min

−1

is standard setting)

Reference Pulse Input

Lit if reference pulse is input

Not lit if no reference pulse is input.

Error Counter Clear Input

Lit when error counter clear signal is input.

Not lit when error counter clear signal is not input.

Power Ready

Lit when main power supply circuit is normal.
Not lit when power is OFF or main power supply circuit is

faulty.