Yaskawa SGDB User Manual

Page 527

Advertising
background image

INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.1 Troubleshooting Problems with Alarm Display cont.

518

J

A.A1

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.A1

Heat sink

overheated

ON

ON

ON

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

A, B, C, D

During servomotor

operation

Occurred when the con-

trol power turned ON.

E

Cause

Remedy

A

The ambient temperature of the

SERVOPACK exceeds 55°C

Alter conditions so that the ambient

temperature goes below 55°C

B

The air flow around the heat sink is bad.

Follow installing method and provide

sufficient surrounding space as specified.

C

Fan stopped.

Replace SERVOPACK.

D

SERVOPACK is running under overload.

Reduce load.

E

SERVOPACK defective.

Replace SERVOPACK.

6