Yaskawa SGDB User Manual

Page 105

Advertising
background image

3.2 Setting Parameters According to Host Controller

93

Cn-14

TCRLMT

Speed Limit for Torque

Control

Unit:

min

−1

Setting

Range: 0 to

10000

Factory

Setting:

10000

For Speed/Torque

Control Only

Sets a motor speed limit value in torque control
mode.

This parameter is used to prevent machine over-
speed during torque control.

Cn-03

VREFGN

Speed Reference

Gain

Unit:

(min

−1

)/V

Setting

Range: 0

to 2000

For Speed/Torque

Control Only

Sets the voltage range of speed reference input V-
REF (1CN-5) according to the output form of the

−1

host controller or external circuit.

The factory setting is rated speed ¦1%/6V.

Motor Series

Factory Setting

SGMG (1500 min

−1

)

250

SGMG (1000 min

−1

)

167

SGMD

333

SGMS, SGM, SGMP

500

3

Speed Control Range for Torque Control

Motor speed

TCRLMT

Torque

Torque

control

range

Reference

speed

(min

−1

)

Set this

slope.

Reference

voltage (V)