3.1 Setting Parameters According to Machine Characteristics

59

3.1.3 Restricting Torque

The SERVOPACK can provide the following torque control:

• Torque restriction

Level 1: To restrict the maximum output torque to protect

the machine or workpiece

Level 2: To restrict torque after the motor moves the

machine to a specified position

• Torque control

Level 3: To always control output torque, not speed

Level 4: To alternately use speed control and torque

control

This section describes how to use levels 1 and 2 of the torque restriction function.

J

How to Set Level 1: Internal Torque Limit

The maximum torque is restricted to the values set in the following parameters.

Cn-08

TLMTF

Forward Rotation

Torque Limit

Unit:

%

Setting

Range: 0 to

800

Factory

Setting:

800

For Speed/Torque

Control and Position

Control

Cn-09

TLMTR

Reverse Rotation

Torque Limit

Unit:

%

Setting

Range: 0 to

800

Factory

Setting:

800

For Speed/Torque

Control and Position

Control

Sets the maximum torque values for
forward rotation and reverse rotation,

respectively.
Sets these parameters when torque
must be restricted according to ma-

chine conditions.
This torque restriction function always
monitors torque, and outputs the signal

shown on the right when the limit value

is reached.
Specifies a torque limit value in terms of

a percentage of the rated torque.
If a value higher than the maximum

torque is set, the maximum torque val-

ue is used.

Output Signal for Torque Restric-
tion Function

• /CLT
• Monitor mode (Un-06) bit 4

Parameter Setting:

(Cn-2D) = jj3, j3j, 3jj

Example of Use: Machine Protection

Motor speed

Torque limit

Torque

Note that too small a torque limit val-
ue will result in torque shortage at ac-

celeration or deceleration.