3.1 Setting Parameters According to Machine Characteristics

61

J

How to Set Level 2: External Torque Limit

First, use a contact input signal to make the torque
(current) limit value set in the parameter valid.
Torque limit can be set separately for forward and
reverse rotation.

To use this function, always set bit 2 of memory
switch Cn-02 to 0 (standard setting). The contact
input speed control function cannot be used.

P CL

ON: 1CN-45 is at

low level.

Torque restriction applies during forward rotation.

Limit value:

Cn-18

P-CL

OFF: 1CN-45 is at

high level.

Torque restriction does not apply during forward

rotation.

N CL

ON: 1CN-46 is at

low level.

Torque restriction applies during reverse rotation.

Limit value:

Cn-19

N-CL

OFF: 1CN-46 is at

high level.

Torque restriction does not apply during reverse

rotation.

Output Signal for Torque Restriction Function

This torque restriction

function outputs the signal

shown on the right.

/CLT

Status indication mode bit data

Monitor mode Un-05 bit 4

Parameter Setting:

Cn-2D = jj3, j3j, 3jj

Examples of Use:
• Forced stopping
• Holding workpiece by robot

Cn-18

CLMIF

Forward External

Torque Limit

Unit:

%

Setting

Range: 0 to

800

Factory

Setting:

100

For Speed/Torque

Control and Position

Control

Cn-19

CLMIR

Reverse External

Torque Limit

Unit:

%

Setting

Range: 0 to

800

Factory

Setting:

100

For Speed/Torque

Control and Position

Control

Sets a torque limit value when torque is restricted by external contact input.
This function is valid when Cn-2B is set to 0, 1, 2, 7, 8, 9, 10, 11.

When /P-CL (1CN-45) is input

Applies torque restriction as specified in Cn-18

When /N-CL (1CN-46) is input

Applies torque restriction as specified in Cn-19

For torque restriction by analog voltage reference, refer to Section 3.2.9 Using Torque
Restriction by Analog Voltage Reference
.

3

SGDB SERVOPACK

Forward

rotation

Without

torque limit

Speed

Torque

With

torque limit

Reverse

rotation

Speed

Torque

Speed

Torque

Speed

Torque

Without

torque limit

With

torque limit

1CN-45

1CN-46

/P-CL

/N-CL

Advertising