Yaskawa SGDB User Manual
Page 431

5.5 Selecting Peripheral Devices
421
from (b)
3)
Select 1CN connector for
reference input.
Connector kit, terminal
block unit, or cable without
connector at one end
Connector kit
Terminal block unit
Cable without
connector at one end
Cable with 1CN
connector and no
connector at the other
end
DE9406969-1
DE9406969-2
What is
SERVOPACK
capacity?
0.3 to
0.5kW
to (c)
Connector-to-terminal
conversion unit
1CN connector kit
JUSP-TA50P
DP9406970
DE9406969-3
4)
Select molded-case circuit breaker
(MCCB) and noise filter.
1m
2m
3m
(3.3ft)
(6.6ft)
(9.8ft)
Use circuit
breaker for
5 A power
capacity.
LF-310
11kW
Noise filter
Use circuit
breaker for
10 A power
capacity.
LF-315
Noise filter
Use circuit
breaker for
12 A power
capacity.
LF-320
Noise filter
Use circuit
breaker for
18 A power
capacity.
LF-330
Noise filter
Use circuit
breaker for
28 A power
capacity.
LF-340
Noise filter
Use circuit
breaker for
32 A power
capacity.
LF-350
Noise filter
Use circuit
breaker for
41 A power
capacity.
LF-360
Noise filter
Use circuit
breaker for
60 A power
capacity.
LF-380K
Noise filter
Use circuit
breaker for
80 A power
capacity.
FN258-100
Noise filter
15kW
0.7 to
1.5kW
2kW
3kW
4.4 to
5kW
6kW
7.5kW
5