Yaskawa SGDB User Manual

Page 534

Advertising
background image

6.2 Troubleshooting

525

J

A.F3

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.F3

Power loss error

OFF

ON

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

A, B

At main circuit power

supply ON.

During servomotor

operation

A, C

Cause

Remedy

A

Although power loss alarm is not

necessary, its parameter is set valid.

Set the parameter Cn-01 bit 5 to 0

B

Time between turning power OFF and back

ON was shorter than 0.5 second.

After turning power OFF, wait for at least

0.5 second, before turning the power back

ON.

C

If any of the following power supply

conditions are met during motor operation:
• Complete power failure : half cycle of sup-

ply frequency

• Voltage drop: full cycle of supply frequency
Note Because of detector lag or detector

margin, there may be no alarm even if
the above values are exceeded.

Check the power supply.
Terms
• Complete power failure=Power failure

where voltage drops to zero.

• Voltage drop=Power failure where voltage

drops, but not to zero.

6

Advertising