10 circuit breaker, 11 noise filter – Yaskawa SGDB User Manual
Page 496
Advertising
SERVO SELECTION AND DATA SHEETS
5.6.11 Noise Filter
486
5.6.10 Circuit Breaker
The customer should purchase a circuit breaker (MCCB) of appropriate capacity.
Use to protect the power lines.
•
Recommended Product
Ground fault detector for motor protection manufactured by
Mitsubishi Electric Co. Ltd.
Type: MN50-CF
5.6.11 Noise Filter
Select the noise filter from the following three types according to the SERVOPACK ca-
pacity.
Install to eliminate external noise from the power lines.
• Dimensional Diagrams
• LF-300 (Three-phase 200 VAC Class)
IN
Rating
Plate
(Ø0.18) (LF-310 to 330)
(Ø0.26) (LF-340 to 360)
M6 (LF-320
to 360)
5