Yaskawa SGDB User Manual

Page 198

Advertising
background image

4.1 Basic Operations

187

J

Using the Setting Mode for Constant Settings (Cn-03 to Cn-2D)

The constant settings (Cn-03 to Cn-23) allow setting of a constant. Check the permitted
range of the constant in Appendix C List of Parameters, before changing the data. The
example below shows how to change user setting Cn-15 from 100 to 85.

For JUSP-OP02A-1

1. Press

DSPL

SET

to select the parameter setting

mode.

2. Select the parameter number to set.

Press the

and

keys to select the digit.

Press the

and

keys to change the val-

ue.

3. Press

DATA

ENTER

to display the current data for the

parameter selected at step 2.

4. Set the required data.

Press the

and

keys to select the digit.

Press the

and

keys to change the val-

ue.

5. Press

DATA

ENTER

to store the data.

6. Press

DATA

ENTER

once more to display the parameter

number again.

7. Repeat steps 2 to 6 as often as required.

4

JUSP-OP02A-1

Setting

Mode

The selected

digit flashes.

Parameter

Number

Data

The selected

digit flashes.

The stored

data flashes.

Parameter

Number

Data

Advertising