Yaskawa SGDB User Manual
Page 198

4.1 Basic Operations
187
J
Using the Setting Mode for Constant Settings (Cn-03 to Cn-2D)
The constant settings (Cn-03 to Cn-23) allow setting of a constant. Check the permitted
range of the constant in Appendix C List of Parameters, before changing the data. The
example below shows how to change user setting Cn-15 from 100 to 85.
For JUSP-OP02A-1
1. Press
DSPL
SET
to select the parameter setting
mode.
2. Select the parameter number to set.
Press the
and
keys to select the digit.
Press the
and
keys to change the val-
ue.
3. Press
DATA
ENTER
to display the current data for the
parameter selected at step 2.
4. Set the required data.
Press the
and
keys to select the digit.
Press the
and
keys to change the val-
ue.
5. Press
DATA
ENTER
to store the data.
6. Press
DATA
ENTER
once more to display the parameter
number again.
7. Repeat steps 2 to 6 as often as required.
4
JUSP-OP02A-1
Setting
Mode
The selected
digit flashes.
Parameter
Number
Data
The selected
digit flashes.
The stored
data flashes.
Parameter
Number
Data