3.8.5 Using an Absolute Encoder cont.

154

NOTE If the SEN signal is to be turned O F F, then ON again, it must remain at high level for at

least 1.3 seconds before being turned OFF.

SEN signal

OFF

ON: High level

ON

1.3 seconds or more

15 ms

or more

OFF

J

Memory Switch to 1 to Select Absolute Encoder

Cn-01 Bit E

Encoder Type Selection

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Sets the encoder type according to the servomotor type to be used.

After changing the memory switch setting, turn the power OFF, then ON.

Motor Type

encoder

specifications

Number of Encoder Pulses Per Revolution

Preset Value

2

Incremental encoder: 8192 pulses per revolution

3

Incremental encoder: 2048 pulses per revolution

0

6

Incremental encoder: 4096 pulses per revolution

0

W

Absolute encoder: 1024 pulses per revolution

1

S

Absolute encoder: 8192 pulses per revolution

1

Use the following parameter to set the number of pulses for the absolute encoder to be
used:

Cn-11

PULSNO

Number of Encoder

Pulses

Unit:

P/R

Setting

Range:

Number of

Encoder

Pulses

For Speed/Torque

Control and Position

Control

Sets the number of encoder pulses according to the servomotor type to be used.

After changing the memory switch setting, turn the power OFF, then ON.

Motor Type

encoder

specifications

Number of Encoder Pulses Per Revolution

Preset Value

2

Incremental encoder: 8192 pulses per revolution

8192

3

Incremental encoder: 2048 pulses per revolution

2048

6

Incremental encoder: 4096 pulses per revolution

4096

W

Absolute encoder: 1024 pulses per revolution

1024

S

Absolute encoder: 8192 pulses per revolution

8192