INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.1.3 Replacing Battery for Absolute Encoder

502

6.1.3 Replacing Battery for Absolute Encoder

Battery replacement is only required for servo systems using an absolute encoder.

Install the battery type recommended below (purchased by the customer) in the host control-
ler to allow the absolute encoder to store position data when the power is turned OFF.

Recommended Battery:

• Lithium Battery

ER 6 V C3, manufactured by Toshiba Battery Co.,
Ltd. 3.6 V, 2000 mAh
Estimated Life: Approximately 10 years

Host Controller

SGDB SERVOPACK

SGMj servomotor

12 bit absolute encoder

Battery

Shielded wire

/PAO

/PBO

/PCO

/PSO

/PA

/PB

/PC

/PS

Note

PS, PSO signals are used only for 12 bit absolute encoder.

The battery voltage is not internally monitored in the SERVOPACK. Therefore, detect low bat-
tery voltage at the host controller.

Minimum required battery voltage is 2.8 V.

Replace the battery according to the following procedure if the battery voltage drops to the
minimum required battery voltage. The battery maintains absolute position data stored in the
encoder.

Battery Replacement Procedure:

1) Turn ON the SERVOPACK and wait at least 3 minutes. The absolute encoder capacitors

are charged.

2) Replace the battery in the host controller. The SERVOPACK power supply can be ON or

OFF during battery replacement.

Note

After completing step 1 above, the absolute encoder will function normally for up to 2 days
with no battery.

6