5.4 Σ -Series Dimensional Drawings

307

• Connector Wiring on Detector Side

Receptacle: MS3102A20-29P
Plug (To be prepared by customer) (L type): MS3108B20-29S or
(Straight type) MS3106B20-29S
Cable Clamp: (To be prepared by customer) MS3057-12A

/Z (C) channel output

Encoder Wiring Specifications

A channel output
/A channel output
B channel output
/B channel output

FG (Frame Ground)

A
B
C
D
E
F
G
H
J

Z (C) channel output

+5V DC

0V

Reset

K
L

P
R
S
T

M
N

0V
3.6V

Note

1) Terminals K to P are not used. Do not connect anything.

2) Receptacle, plug and cable clamp are common regardless of motor capacity.

• Connector Wiring on Motor Side

Phase U
Phase V
Phase W
Ground terminal

Motor Wiring Specifications

A
B
C
D

Note

Receptacle, plug and cable clamp differ depending on the capacity. Refer to 6) Connectors
on Detector and Motor Sides (page 392).