APPLICATIONS OF Σ-SERIES PRODUCTS

3.1.2 Setting the Overtravel Limit Function

56

3.1.2 Setting the Overtravel Limit Function

The overtravel limit function forces the moving part of the machine to stop when it ex-
ceeds the movable range.

J

Using the Overtravel Limit Function

To use the overtravel limit function, connect the following input signal terminals correctly.

Input P-OT 1CN-42

Forward Rotation Prohibited

(Forward Overtravel)

For Speed/Torque

Control and

Position Control

Input N-OT 1CN-43

Reverse Rotation Prohibited

(Reverse Overtravel)

For Speed/Torque

Control and

Position Control

Input terminals for overtravel limit switch.

For linear motion, connect a limit switch to prevent
damage to the machine.

P-OT

ON: 1CN-42 is

at low level.

Forward rotation allowed. Normal operation status.

OFF: 1CN-42

is at high level.

Forward rotation prohibited (reverse rotation allowed).

N-OT

ON: 1CN-43 is

at low level.

Reverse rotation allowed. Normal operation status.

OFF: 1CN-43

is at high level.

Reverse rotation prohibited (forward rotation allowed).

J

Specifying whether Input Signals for Overtravel are to be Used

Use the following parameters (memory switch) to specify whether input signals for over-
travel are to be used.

Cn-01 Bit 2

Use of P-OT Input Signal

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Cn-01 Bit 3

Use of N-OT Input Signal

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Specifies whether the P-OT input signal for pro-
hibiting forward rotation at overtravel (1CN-42) is
to be used and whether the N-OT input signal for
prohibiting

reverse

rotation

at

overtravel

(1CN-43) is to be used.

Specifies “1” when external short-circuit wiring is
to be omitted.

3

Reverse

rotation side

Forward

rotation side

SGDB

SERVOPACK

Limit switch

SGMj

servomotor

1CN-42

1CN-43

SGDB SERVOPACK

The short-circuit wiring shown in the

figure can be omitted when P-OT and

N-OT are not used.

1CN

-42

-43

Advertising