6.2 Troubleshooting
505
J
A.02
Display and Outputs
Digital Operator
Di l
d
Alarm Output
g
p
Display and
Alarm Name
Alarm Code Output
Alarm Output
Alarm Name
ALO1
ALO2
ALO3
p
A.02
Parameters
breakdown
OFF
OFF
OFF
OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
At power ON
A
,
B
Cause
Remedy
A
Power turned OFF during parameter write.
Alarm occurred next power ON.
Replace SERVOPACK.
B
Circuit board (1PWB) defective
Replace SERVOPACK.
J
A.04
Display and Outputs
Digital Operator
Di l
d
Alarm Output
g
p
Display and
Alarm Name
Alarm Code Output
Alarm Output
Alarm Name
ALO1
ALO2
ALO3
p
A.04
Parameter setting
error
OFF
OFF
OFF
OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
At power ON
A
,
B
Cause
Remedy
A
An out-of-range parameter was previously
set or loaded.
Reset all parameters in range. Otherwise,
re-load correct parameters.
B
Circuit board (1PWB) defective
Replace SERVOPACK.