4 . 2 Using the Functions
211
Follow the procedure below to manually adjust the reference voltage.
For JUSP-OP02A-1
1. Press
DSPL
SET
to select the parameter setting
mode.
2. Select the parameter number Cn-00.
(Parameter Cn-00 is selected when the power
is turned ON.)
Press the
and
keys to select the
digit.
Press
and
keys to change the
value.
3. Press
DATA
ENTER
to display the current data for the
parameter Cn-00.
4. Press the
and
keys to change the data
to 03.
5. Press
DSPL
SET
to select the speed reference off-
set manual adjustment mode.
The amount of speed reference offset is dis-
played.
6. Press the
and
keys to adjust the
amount of offset.
(Adjust the speed references.)
7. Press
DSPL
SET
to select the torque reference off-
set manual adjustment mode.
The amount of torque reference offset is dis-
played.
8. Press the
and
keys to adjust the
amount of offset.
(Adjust the torque references.)
4
JUSP-OP02A-1
Setting Mode
Select Cn-00.
The selected digit
flashes.
Parameter Number
Data
Set to 00-03.
keys to change the
value.
Press the
Speed Reference
Offset Manual
Adjustment Mode