Yaskawa SGDB User Manual

Page 55

Advertising
background image

2.4 Conducting a Test Run

43

J

Using the Digital Operator

Operate the motor with the Digital Operator. Check
that the motor runs normally.

Refer to Section 4.2.2 Operation Using the Digital
Operator
.

J

Connecting Signal Lines

Connect connector 1CN as follows:

1. Turn the power OFF.

2. Connect connector 1CN.

3. Turn the power ON again.

J

Checking Input Signals.

Check the input signal wiring in monitor mode.
For the checking method, refer to Section
4.1.7 Operation in Monitor Mode
.

• Checking method

Turn each connected signal line ON and
OFF to check that the monitor bit display
changes accordingly.

Input Signal

ON/OFF

Monitor Bit Display

High level or open

OFF

Extinguished

0 V level

ON

Lit

If the signal lines below are not wired correctly, the motor fails to rotate. Always wire
them correctly. (If signal lines are not to be used, short them as necessary.)

P-OT

1CN-42

Motor can rotate in forward direction when this input signal is at 0 V.

N-OT

1CN-43

Motor can reverse when this input signal is at 0 V.

S-ON

1CN-40

Servo is turned ON when this input signal is at 0 V. However, leave

the servo in OFF status.

2

Operation by Digital Operator

If an alarm occurs, the power supply

circuit, motor wiring, or encoder

wiring is incorrect.

Connect

connector

1CN.

Internal status bit display

(Un-05, Un-06)

Example of

Un-05

The memory switch can be

used to

eliminate the need

for

external short-circuits in

wiring (see pages 56 and

131).

Advertising