Yaskawa SGDB User Manual
Page 209
USING THE DIGITAL OPERATOR
4.2.2 Operation Using the Digital Operator cont.
198
J
Operation Using the Digital Operator
Use the following procedure to operate the motor from the Digital Operator
For JUSP-OP02A-1
1. Press
DSPL
SET
to select the parameter setting
mode.
2. Select the parameter number Cn-00.
(Parameter Cn-00 is selected when the power
is turned ON.)
Press the
and
keys to select the
digit.
Press the
and
keys to change the value.
3. Press
DATA
ENTER
to display the current data for the
parameter Cn-00.
4. Press the
and
keys to change the data
to 00.
(This parameter is set to 00 when the power is
turned ON.)
5. Press
DSPL
SET
to set the Digital Operator in op-
eration mode. Operation is now possible under
Digital Operator control.
6. Press
JOG
SVON
to set the servo ON status (motor
power turned ON).
4
JUSP-OP02A-1
Setting Mode
Select Cn-00.
The selected digit
flashes.
Parameter
Number
Data
Set to 00-00.
keys to change the
value.
Press the
Display for operation mode from
Digital Operator
to change.
Servo ON
- motor ON
Servo OFF
- base block
Press