3.2 Setting Parameters According to Host Controller

71

Cn-02

Motor Reverse Run

Reference

Motor Forward Run

Reference

Refer-

ence

Pulse

Form

Input

Pulse

Multipli-

er

Bit D

Motor Reverse Run

Reference

Motor Forward Run

Reference

Refer-

ence

Pulse

Form

Input

Pulse

Multipli-

er

Bit

3

Bit

4

Bit

5

0

0

0

Sign +

pulse

train

(1CN-7)

(1CN-11)

(1CN-7)

(1CN-11)

1

0

1

0

¢

1

Two-

phase

pulse

1

(Nega-

tive log-

ic set-

0

1

1

¢

2

pulse

train

with 90°

phase

(1CN-7)

(1CN-11)

(1CN-7)

(1CN 11)

ic set

ting)

1

0

0

¢

4

phase

differ-

ence

(1CN-11)

(1CN-11)

0

0

1

CW

pulse +

CCW

pulse

(1CN-7)

(1CN-11)

(1CN-7)

(1CN-11)

Input Pulse Multiply Function:

When the reference form is two-phase pulse train
with 90° phase difference, the input pulse multiply

function can be used.

The electronic gear function can also be used to
convert input pulses.

Example of I/O Signal Generation Timing

Servo ON

Base block

Sign +

pulse train

Release

t1 ≤ 30 ms

t2 ≤ 6 ms

(When parameter

Cn-12 is set to 0)

t3 ≥ 40 ms

PG pulse

t4, t5, t6 ≤ 2 ms

t7 ≥ 20 μs

Note The interval from the time the servo ON signal is turned ON until a reference pulse is

input must be at least 40 ms. Otherwise, the reference pulse may not be input.

The error counter clear (CLR) signal must be ON for at least 20 μs. Otherwise, it be-

comes invalid.

1CN-11

1CN-7

t

7

/COIN

3

Number of

motor move

pulses

x 4

x 2

x 1

Input reference pulse

(1CN-7)