2 main circuit wiring and power on sequence – Yaskawa SGDB User Manual

Page 46

Advertising
background image

BASIC USES OF Σ-SERIES PRODUCTS

2.3.2 Main Circuit Wiring and Power ON Sequence

34

2.3.2 Main Circuit Wiring and Power ON Sequence

The following diagram shows a typical example of wiring the main circuit for Σ-Series

products:

1MCCB: Circuit breaker (for inverter type)

FIL:

Noise filter

1MC:

Contactor

1Ry:

Relay

1PL:

Lamp for display

1SUP:

Surge suppressor

1D:

Flywheel diode

(Alarm lamp)

Main circuit

power

Main circuit power

Three-phase 200 to 230 VAC

(50/60 Hz)

+ 10%

15%

SERVOPACK

SGDB-jjADj

The following table shows the name and description of each main circuit terminal:

Terminal

Symbol

Name

Description

R, S, T

Main power input

terminals

Three-phase 200 to 230 VAC

, 50/60Hz

+ 10

15

%

U, V, W

Motor connection

terminal

Used to connect motor

r, t

Control power

input terminals

Single phase 200 to 230 VAC

, 50/60Hz

+ 10

15

%

×2

Ground terminal

Connected to earth. (For power ground and motor ground).

P, B

Regenerative

resistor unit

connection

terminal

Normally, external connection is not required.

P1, B

Regenerative

resistor unit

connection

terminal

Terminal used to connect regenerative resistor for

SERVOPACK with power capacity more than 6 kW.

N

Main circuit minus

side terminal.

Normally, external connection is not required.

Note

P1 terminal is not available for SERVOPACK with power capacity less than 5 kW.

2

Advertising