Yaskawa SGDB User Manual

Page 569

Advertising
background image

563

Category

Re-

mar

ks

Factory

Setting

Upper

Limit

Lower

Limit

Unit

Name

Code

Parame-

ter No.

Cn-06

EMGTRQ

Emergency stop

torque

%

0

800

800

Cn-13

TCRFGN

Torque reference gain

0.1 V/

100%

10

100

30

Cn-14

TCRLMT

Speed limit for torque

control

min

−1

0

10000

10000

Sequence Re-

l

d

Cn-2D

OUTSEL

Output signal selection *1

110

666

210

q

lated

Constants

Cn-0B

TGONLV

Zero-speed level

min

−1

1

10000

20

Constants

Cn-29

ZCLVL

Zero clamp level

min

−1

0

10000

10

Cn-22

VCMPLV

Speed coincidence

signal output range

min

−1

0

100

10

Cn-1B

COINLV

Positioning completion

range

reference

unit

0

250

7

Cn-1E

OVERLV

Overflow

256 refer-

ence unit

1

32767

1024

Cn-12

BRKTIM

Time delay from brake

reference until servo

OFF

10 ms

0

50

0

Cn-15

BRKSPD

Speed level for brake

reference output dur-

ing motor operation

min

−1

0

10000

100

Cn-16

BRKWAI

Output timing of brake

reference during motor

operation

10 ms

10

100

50

Other

C

Cn-10

JOGSPD

Jog speed

min

−1

0

10000

500

Constants

Cn-1F

SPEED1

1st speed (contact in-

put speed control)

min

−1

0

10000

100

Cn-20

SPEED2

2nd speed (contact in-

put speed control)

min

−1

0

10000

200

Cn-21

SPEED3

3rd speed (contact in-

put speed control)

min

−1

0

10000

300

Cn-2C

PGPWR

PG power supply volt-

age change

0.1 mV

52000

58000

52500

: Parameters must be set and checked before turning the motor power ON.

Note

*1 Refer to page 568.
*2 After changing the setting, always turn the power OFF, then ON. This makes the new

setting valid.

*3 Automatically set by auto tuning function
*4 To use soft start function, always set both Cn-07 and Cn-23.
*5 6.0kW or less : 4, 7.5kW : 8, 11.0 to 15.0kW : 16