Yaskawa SGDB User Manual

Page 141

Advertising
background image

3.7 Forming a Protective Sequence

129

J

Relationship between Alarm Display and Alarm Code Output

Alarm Display and Alarm Code Output:

Alarm

Alarm Code Output

Servo

Alarm

(ALM)

Alarm Type

Alarm Description

Alarm

Display

ALO1 ALO2 ALO3

(ALM)

Out-

put

Alarm Type

Alarm Description

¢

¢

¢

¢

User

constant

error

An absolute encoder error

occurred or parameter is

faulty.

¢

¢

¢

Overcurrent

Overcurrent flowed thorough

the main circuit.

SERVOPACK overheated.

¢

¢

Regenerative

error.

Position error

pulse

overflow

Regenerative circuit is faulty.
The number of pulses in er-

ror counter has exceeded

the preset value.

¢

¢

¢

Main power

voltage error

Main circuit DC voltage has

exceeded approximately

420 V.

¢

¢

Overspeed

Motor speed has exceeded

the maximum allowable

speed.

¢

Overload

Motor and SERVOPACK are

overloaded.

¢

¢

Overrun

Disconnec-

tion of PG

signal line

Overrun occurred due to mo-

tor or encoder signal wiring

faults.

Encoder signal line is dis-

connected.

¢

¢

¢

¢

Absolute en-

coder error

Absolute encoder is faulty.

¢

Heatsink

overheat

SERVOPACK heat sink

overheated.

¢

¢

¢

¢

Reference

input read er-

ror

Reference input failed to be

detected.

¢

¢

¢

Power line

open phase

One phase is missing from

main circuit power supply.

U d fi d

Digital Oper-

ator trans-

mission error

Communication error oc-

curred between Digital Oper-

ator and SERVOPACK.

Undefined

mission error ator and SERVOPACK.

¢

¢

¢

No error

○ : Output transistor is ON
¢

: Output transistor is OFF (Alarm state)

* : Displays an alarm category number.
For details, refer to Appendix D List of Alarm Displays.