Yaskawa SGDB User Manual

Page 401

Advertising
background image

5.4 Σ -Series Dimensional Drawings

391

5) The electromagnetic brake is only to hold the load in position and cannot be used to stop

the motor.

• Details of Motor and Encoder Plugs

A channel output

Blue

/A channel output

White/Blue

B channel output

Yellow

/B channel output

White/Yellow
Green
White/Green
Black
Red

FG (Frame Ground)

Green/Yellow

/Z channel output

Z channel output

0 V (power supply)
+5 V (power supply)

1
2
3
4
5
6
7
8
9

10
11

(12)

13
14
15

S channel output
/S channel output

Purple
White/Purple

(Capacitor reset)

(Gray)

Reset

White/Gray

0V(battery)
3.6V(battery)

White/Orange
Orange

Phase U

Red

Phase V

White

Phase W

Blue

FG

Green/Yellow

Motor Wiring Specifications

Absolute Encoder Wiring Specifications

Plug: 172171-1 (AMP)

Pin: 170359-1 or 170363-1
Connected to

Cap :172163-1

Socket: 170361-1 or 170365-1

1
2
3
4
5
6

Brake terminal
Brake terminal

Black
Black

Terminal to discharge capacitor for product dispatch. Do not
use.

*

*

Motor Plug

Encoder Plug

Socket: 350536-6 or 350550-6

Pin: No.1 to No.4

350218-6 or

350547-6

Cap: 350781-1

Plug : 350715-1 (AMP)

Connected to

Pin: No.5 to No.6

350561-1 or

350690-1

5

Advertising