BASIC USES OF Σ-SERIES PRODUCTS

2.3.3 Connection to Host Controller

36

2.3.3 Connection to Host Controller

The SGDB SERVOPACK can be connected to the following host controllers. For details,
refer to the technical documentation for the host controller.

• MP920

• GL-Series Positioning Module B2833

• GL-Series Positioning Module B2813

• OMRON Position Control Unit

• MITSUBISHI Positioning Unit

The following diagrams show connection examples with the host controllers manufac-
tured by OMRON and MITSUBISHI.

J

Connection to OMRON Position Control Unit C500-NC222

SERVOPACK for Speed/Torque Control

I/O Power Supply

X-axis (Y-axis)

SERVOPACK

* These signals are output for approximately two seconds when the power is turned

ON. Take this into consideration when designing a power ON sequence. Relay 1Ry is

used to stop main circuit power supply to SERVOPACK.

Note The signals shown here are applicable only to OMRON Sequencer

C500-NC222 and Yaskawa SERVOPACK SGDB-VVADV.

C500-NC222

(Made by OMRON)

(ON when

proximity is

detected)

(ON when

positioning is

stopped)

SGDB-jjADj

/PAO

/PBO

/PCO

/S-ON

(T-REF)

X-/A

X-/B

X-/C

2

Speed/Torque