7 operation in monitor mode – Yaskawa SGDB User Manual

Page 202

Advertising
background image

4.1 Basic Operations

191

4.1.7 Operation in Monitor Mode

The monitor mode allows the reference values input into the SERVOPACK, I/O signal status,
and SERVOPACK internal status to be monitored.
The monitor mode can be set during motor operation.

J

Using the Monitor Mode

The example below shows how to display 1500, the contents of monitor number Un-00.

For JUSP-OP02A-1

1. Press

DSPL

SET

to select the monitor mode

2. Press the

and

keys to select the moni-

tor number to display.

3. Press

DATA

ENTER

to display the data for the monitor

number selected at step 2.

4. Press

DATA

ENTER

once more to display the monitor

number again.

For JUSP-OP03A

1. Press

MODE/SET

to select the monitor mode.

2. Press the

UP

and

DOWN

keys to select the moni-

tor number to display.

3. Press

DATA

to display the data for the monitor

number selected at step 2.

4. Press

DATA

once more to display the monitor

number again.

4

JUSP-OP02A-1

Monitor

Mode

Monitor

Number

Data

Monitor

Number

Data

JUSP-OP03A

Monitor

Mode

Monitor

Number

Data

Monitor

Number

Data

Advertising