FOR FIRST-TIME USERS OF AC SERVOS

1.3.3 How to Use the SGDB SERVOPACKs cont.

14

The host controller can send a position reference (pulse train) to the SERVOPACK to per-
form positioning or interpolation.
This type of SERVOPACK contains a position control loop.

Parameters can be used to select either of the following pulse trains:

(1) Code and pulse train

(2) Two-phase pulse train with 90° phase difference

(3) Forward and reverse pulse trains

The host controller receives a pulse train (position information) from the SERVOPACK
and uses it to monitor the position.

J

Setting Parameters

A Digital Operator can be used to set parameters for a SERVOPACK as follows:

• Setting parameters to enable or disable each function

• Setting parameters required for functions to be used

Set parameters according to the servo system to be set up.