Yaskawa SGDB User Manual

Page 223

Advertising
background image

USING THE DIGITAL OPERATOR

4.2.5 Reference Offset Manual Adjustment Mode cont.

212

9. Press

DSPL

SET

to return to the parameter data

display.

10.Press

DATA

ENTER

to return to the setting mode dis-

play. This ends the reference offset manual ad-
justment.

For JUSP-OP03A

1. Press

MODE/SET

to select the parameter setting

mode.

2. Press the

UP

and

DOWN

keys to select the pa-

rameter number Cn-00.
(Parameter Cn-00 is selected when the power
is turned ON.)

3. Press

DATA

to display the current data for the pa-

rameter Cn-00.

4. Press the

UP

and

DOWN

keys to change the

data to 03.

5. Press

MODE/SET

to select the speed reference off-

set manual adjustment mode.
The amount of speed reference offset is dis-
played.

6. Press the

UP

and

DOWN

keys to adjust the

amount of offset.

(Adjust the speed references.)

7. Press

MODE/SET

to select the torque reference off-

set manual adjustment mode.
The amount of torque reference offset is dis-
played.

8. Press the

UP

and

DOWN

keys to adjust the

amount of offset.(Adjust the torque references.)

4

Setting Mode Display

JUSP-OP03A

Setting Mode

Select Cn-00.

Parameter Number

Data

Set to 00-03.

Value changes

rapidly when

key held down.

Speed Reference

Offset Manual

Adjustment Mode

Advertising