USING THE DIGITAL OPERATOR
4.2.5 Reference Offset Manual Adjustment Mode cont.
212
9. Press
DSPL
SET
to return to the parameter data
display.
10.Press
DATA
ENTER
to return to the setting mode dis-
play. This ends the reference offset manual ad-
justment.
For JUSP-OP03A
1. Press
MODE/SET
to select the parameter setting
mode.
2. Press the
UP
and
DOWN
keys to select the pa-
rameter number Cn-00.
(Parameter Cn-00 is selected when the power
is turned ON.)
3. Press
DATA
to display the current data for the pa-
rameter Cn-00.
4. Press the
UP
and
DOWN
keys to change the
data to 03.
5. Press
MODE/SET
to select the speed reference off-
set manual adjustment mode.
The amount of speed reference offset is dis-
played.
6. Press the
UP
and
DOWN
keys to adjust the
amount of offset.
(Adjust the speed references.)
7. Press
MODE/SET
to select the torque reference off-
set manual adjustment mode.
The amount of torque reference offset is dis-
played.
8. Press the
UP
and
DOWN
keys to adjust the
amount of offset.(Adjust the torque references.)
4
Setting Mode Display
JUSP-OP03A
Setting Mode
Select Cn-00.
Parameter Number
Data
Set to 00-03.
Value changes
rapidly when
key held down.
Speed Reference