6.2 Troubleshooting
507
J
A.30
Display and Outputs
Digital Operator
Di l
d
Alarm Output
g
p
Display and
Alarm Name
Alarm Code Output
Alarm Output
Alarm Name
ALO1
ALO2
ALO3
p
A.30
Regenerative
error detection
ON
ON
OFF
OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
During servomotor
operation
Occurred when the con-
trol power turned ON
A
,
B
D
Occurred approximate-
ly 1 second after the
main circuit power ON.
A, B, C
Cause
Remedy
A
Regenerative transistor is abnormal.
Replace SERVOPACK.
B
Disconnection of the regenerative resistor
unit.
Replace SERVOPACK or regenerative
resistor unit.
C
Regenerative resistor unit disconnected
(for more than 6.0 kW).
Check wiring of the regenerative resistor
unit.
D
SERVOPACK defective.
Replace SERVOPACK.
6