6.2 Troubleshooting

507

J

A.30

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.30

Regenerative

error detection

ON

ON

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

During servomotor

operation

Occurred when the con-

trol power turned ON

A

,

B

D

Occurred approximate-

ly 1 second after the

main circuit power ON.

A, B, C

Cause

Remedy

A

Regenerative transistor is abnormal.

Replace SERVOPACK.

B

Disconnection of the regenerative resistor

unit.

Replace SERVOPACK or regenerative

resistor unit.

C

Regenerative resistor unit disconnected

(for more than 6.0 kW).

Check wiring of the regenerative resistor

unit.

D

SERVOPACK defective.

Replace SERVOPACK.