APPLICATIONS OF Σ-SERIES PRODUCTS

3.1.3 Restricting Torque

62

• Using /P-CL and /N-CL Signals

This section describes how to use input signals /P-CL and /N-CL as torque limit input sig-
nals.

I/O power supply

SGDB SERVOPACK

Photocoupler

Host controller

1CN-47

1CN-45

1CN-46

5 mA

/P-CL

/N-CL

Input /P-CL 1CN-45

Forward External Torque Limit

Input (Speed Selection 1)

For Speed/Torque

Control and

Position Control

Input /N-CL 1CN-46

Reverse External Torque Limit

Input (Speed Selection 2)

For Speed/Torque

Control and

Position Control

These signals are for forward and reverse exter-
nal torque (current) limit input.

This function is useful in forced stopping.

P CL

ON: 1CN-45 is at

low level.

Torque restriction applies during forward rotation.

Limit value:

Cn-18

P-CL

OFF: 1CN-45 is at

high level.

Torque restriction does not apply during forward

rotation. Normal operation status.

N CL

ON: 1CN-46 is at

low level.

Torque restriction applies during reverse rotation.

Limit value:

Cn-19

N-CL

OFF: 1CN-46 is at

high level.

Torque restriction does not apply during reverse

rotation. Normal operation status.

The signal shown on the above are output while torque is being restricted.

Note This function is changed to another function depending on the setting of memory

switch Cn-2B (see below).

3

Output Signal for Torque

Restriction Function

• /CLT
• Status indication mode bit data

• Monitor mode Un-05 bit 4

• Parameter Setting:

Cn-2D = jj3, j3j, 3jj