3.8 Special Wiring

149

3.8.3 Using More Than One Servo Drive

J

Example of Wiring More than One Servo Drive

Power supply

Noise filter

Power

OFF

Power

ON

SGDB

SERVOPACK

SGMj

servomotor

Note Wire the SERVOPACK

so that terminal S is the

grounding phase.

SGMj

servomotor

SGMj

servomotor

SGDB

SERVOPACK

SGDB

SERVOPACK

Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to en-
able alarm detection relay 1RY to operate. This is because ALM is a logical complement
output signal, so the output transistor is turned OFF when the system enters an alarm
state.

The output transistor is turned OFF when the ALM output signal invokes alarm state.