APPLICATIONS OF Σ-SERIES PRODUCTS

3.7.6 Using OL Warning and Alarm Output Signals

138

3.7.6 Using OL Warning and Alarm Output Signals

This section describes how to wire and use photocoupler output signals OLWRN (over-
load warning) and OL (overload alarm).
These two output signals are output when operation under the rated current or more con-
tinues for a certain period of time. The overload warning signal is output in 20% of the
time required to output the overload alarm signal.

Operating time

(seconds)

Instantaneous peak current

Rated current

Overload Alarm level

Overload warning level

Current

SGDB SERVOPACK

I/O power supply

Photocoupler Output

Per output:

Maximum operation

voltage: 30 VDC

Maximum output

current: 50 mADC

OLWRN+

(OL+)

OLWRN−

(OL−)

Output /OLWRN

Overload Warning Output

For Speed/Torque

Control and

Position Control

Output OL

Overload Alarm Output

For Speed/Torque

Control and

Position Control

OLWRN is an overload warning output signal, and OL is an overload alarm output signal.

ON
status:

Circuit is closed or signal is at low level. Normal state

OFF
status:

Circuit is open or signal is at high level.

Warning or alarm state

Use the following parameter to specify the pin to which the signal is to be output.

Cn-2D

OUTSEL

Output

signal

selection

Setting Range:

110 to 666

Factory

Setting:

210

For

Speed/Torque

Control and

Position Control

This parameter is used to specify a function signal as the 1CN output signal.