Yaskawa SGDB User Manual

Page 77

Advertising
background image

3.2 Setting Parameters According to Host Controller

65

J

Example of Input Circuit

(See the figure on the right)

For noise control, always use twisted-pair
cables.

Recommended Variable Resistor for Speed Setting:
Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

When position control is performed by a host con-
troller such as a programmable controller, con-
nect V-REF and SG to speed reference output ter-
minals on the host controller. In this case, adjust
Cn-03 according to output voltage specifications.

The internal ¦12 V power supply can be used.

+12V

1CN-24

1CN-23

−12V

Maximum output current: 30mA
Voltage: 12V¦2V

Set parameter Cn-2B to select one of the following control modes.

Cn-2B

Control Mode Selection

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Cn-2B

Setting

Control Method

0

Speed Control
This is normal speed control.
• Speed reference is input from V-REF (1CN-5).
• /P-CON (1CN-41) signal is used to switch

between P control and PI control.

SGDB SERVOPACK

Speed

reference

P/PI

changeover

1CN-5

1CN-41

/P-CON

0

1CN-41 is

open

PI control

1CN-41 is

at 0 V

P control

3

1/2 W or more

SGDB SERVOPACK

1CN-5

1CN-6

SG

Host controller

SERVOPACK

Speed

reference

output

terminals

Feedback

pulse input

terminals

↕P: Represents twisted-pair cables

/PBO

/PAO

1CN-5

1CN-6

1CN-33

1CN-34

1CN-35

1CN-36

470Ω 1/2W or more

Advertising