APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.6 Using Contact Input Speed Control

84

Setting

Meaning

Input Signal

0, 1, 2,

7 8 9

Does not use

the contact

/P-CON (1CN-41)

Used to switch between P control and PI

control and to perform other functions.

7, 8, 9,

10 11

the contact

input speed

/P-CL (1CN-45)

Used for forward external current limit input

10, 11

input speed

control function.

/N-CL (1CN-46)

Used for reverse external current limit input

Uses the
contact input
speed co t ol

0: OFF, 1: ON

speed control
function.
Note
In

the

/P-CON

/P-CL

/N-CL Speed Setting

Note In

the

case

of

the posi-

Direction

of rotation

0

0

0 reference and so on

3, 4, 5,

6

the posi
tion con-
trol type,
the refer

0: Forward

1: Reverse

0

1

Cn-1F, SPEED1

the refer-
ence
pulse in-

1

1

Cn-20, SPEED2

pulse in
hibit func-
tion

(IN-

HIBIT)

1

0

Cn-21, SPEED3

HIBIT)
cannot be
used.

2. Set three motor speeds in the following parameters.

Cn-1F

SPEED1

1st Speed (Contact

Input Speed Control)

Unit:

min

−1

Setting

Range: 0 to

10000

Factory

Setting:

100

For Speed Control only

Cn-20

SPEED2

2nd Speed (Contact

Input Speed Control)

Unit:

min

−1

Setting

Range: 0 to

10000

Factory

Setting:

200

For Speed Control only

Cn-21

SPEED3

3rd Speed (Contact

Input Speed Control)

Unit:

min

−1

Setting

Range: 0 to

10000

Factory

Setting:

300

For Speed Control only

Use these parameters to set motor speeds
when the contact input speed control function
is used.
If a value higher than the maximum speed is
set, the maximum speed value is used.

Speed selection input signals /P-CL (1CN-45)
and /N-CL (1CN-46), and rotation direction
selection signal /P-CON (1CN-41) enable the
motor to run at the preset speeds.

3. Set the soft start time.

Cn-07

SFSACC

Soft Start Time

(Acceleration)

Unit:

ms

Setting

Range: 0

to 10000

Factory

Setting: 0

For Speed Control only

Cn-23

SFSDEC

Soft Start Time

(Deceleration)

Unit:

ms

Setting

Range: 0

to 10000

Factory

Setting: 0

For Speed Control only

3

Contact input speed control

SERVOPACK

Contact

input

Run the

motor at

internally

set speed

Servomotor