3.1 Setting Parameters According to Machine Characteristics

55

J

Setting Reverse Rotation Mode

Reverse rotation mode can be set in either of the following two ways. Normally, method 1
is easier to use.

Method 1: Setting Memory Switch

Set bit 0 of memory switch Cn-02 to select reverse rotation mode.

Cn-02 Bit 0

Rotation Direction

Selection

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Set the direction of rotation.

Setting

Meaning

0

Forward rotation is

defined as

counterclockwise

rotation when viewed

from the drive end.

(Standard

setting)

1

Forward rotation is

defined as clockwise

rotation when viewed

from the drive end.

(Reverse

rotation

mode)

Method 2: Shorting the Wiring in the 2CN Connector

Reverse rotation mode can be set for the 2CN

connector for the encoder. This method is used

to standardize parameter settings without using

the memory switch.

In this case, reverse rotation

mode is set regardless of the

memory switch setting.

SGDB

SERVOPACK

SGMj servomotor

Encoder

Short 2CN-1 and 2CN-7 in

the 2CN connector.