Yaskawa SGDB User Manual

Page 194

Advertising
background image

4.1 Basic Operations

183

Bit Data

Description

Control Power ON

Lit when SERVOPACK control power ON. Not lit when

SERVOPACK control power OFF.

Base Block

Lit for base block. Not lit at servo ON.

Speed Coincidence

Lit if motor speed reaches speed reference. Otherwise,

not lit.

TGON

Lit if motor speed exceeds preset value.

Not lit if motor speed is below preset value

Not lit if motor speed is below preset value.

Preset value: Set in Cn-0B (20 min

−1

is factory setting)

Speed Reference Input

Lit if input speed reference exceeds preset value.

Not lit if input speed reference is below preset value.

Specified value: Set in Cn-0B (20 min

−1

is factory setting)

Torque Reference Input

Lit if input torque reference exceeds preset value.

Not lit if input torque reference is below preset value.

Preset value: Set in Cn-0B (10% rated torque is standard

setting)
(Used for torque feed−forward or current restriction)

Power Ready

Lit when main power supply circuit is normal.
Not lit when power is OFF or main power supply circuit is

faulty.

For Position Control

Code

Bit Data

Positioning Complete

Base Block

Control Power ON

Reference Pulse Input

Error Counter Clear Input

Power Ready

TGON

Code

Status

Base block

Servo OFF

Run

Servo ON

Forward Rotation Prohibited

1CN-42 (P-OT) OFF. See Cn-01 Bit 2 (page 57).

Reverse Rotation Prohibited

1CN-43 (N-OT) OFF. See Cn-01 Bit 3 (page 57).

Alarm Status

Displays the alarm number. See the table of alarms on page 196.

4

Advertising