34 unbind/bind ethernet module mxi1, 5drive interface – Lenze E94AxPExxxx User Manual
Page 130
![background image](/manuals/566084/130/background.png)
5
Drive interface
5.2
Device commands
130
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.34
Unbind/bind Ethernet module MXI1
The
= "101: Unbind/bind Ethernet module: MXI1" device command is used to reinitialise
the Ethernet interface of an Ethernet communication module in module slot MXI1, e. g. to accept a
newly set IP or gateway address without mains switching.
Tip!
Detailed information on the Ethernet communication module (E94AYCEN) can be found in
the "Ethernet" Communication Manual.
Possible status displays for this device command
Related device commands
Unbind/bind Ethernet module MXI2
Status (
Meaning
6653186 Device command in process
6619136 Device command executed successfully
6619137 General error