3 initial commissioning, Initial commissioning, 3commissioning – Lenze E94AxPExxxx User Manual

Page 29

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

29

3

Commissioning

3.3

Initial commissioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.3

Initial commissioning

More (optional) worksteps

Worksteps
Parameterising motor control:

1. Read out the motor data of the controller or select them via the »Engineer« motor catalogue.

• If the motor connected to the controller is provided with an electronic nameplate (ENP), all motor

data are automatically read out from the ENP and a selection in the motor catalogue is not required.

Reading out motor data from the controller

( 165)

• If a motor without ENP or a motor by a third-party manufacturer is used, the selection is carried out

via the »Engineer« motor catalogue.

Selecting a motor from the motor catalogue in the »Engineer«

( 166)

2.

Select motor control

.

( 169)

• Servo control is preset for the synchronous motor.

3.

Adjusting motor and controller to each other ( 171)

4. Carry out settings for selected motor control.

• For this see description for the corresponding motor control:

Servo control (SC)

Sensorless vector control (SLVC)

()

V/f control (VFCplus)

()

V/f control (VFCplus)

()

Optimise control mode:

7. Optimise control mode of the selected motor control.

• By means of traversing profile from the application and oscilloscope.

• For this see description for the corresponding motor control:

Servo control (SC)

Sensorless vector control (SLVC)

()

V/f control (VFCplus)

()

V/f control (VFCplus)

()

Save project and parameter set:

8. Execute device command

C00002

= "11: Save start parameters".

9. Save »Engineer« project.

Worksteps
Establish network:

1. Insert network and machine application into the »Engineer« project.
2. Interconnect port blocks reasonably to each other within the machine application.
3. Configure network (set addresses, baud rate, and process data channels in a reasonable manner).
4. Establish communication with the control system.
5. Establish communication with other drive components (e.g. HMIs, I/O extensions and other controllers).

Advertising