C00635 | resp to new firmw. standard dev, C00636 | resp. to new module in mxi1, C00637 | resp. to new module in mxi2 – Lenze E94AxPExxxx User Manual

Page 831: C00640 | resp. to pole pos. id. monit, C00640, 15 parameter reference

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

831

15

Parameter reference

15.2

Parameter list | C00635

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00635

C00636

C00637

C00640

Parameter | Name:

C00635 | Resp to new firmw. standard dev.

Data type: UNSIGNED_32

Index: 23940

d

= 5D84

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00637 | Resp. to new module in MXI2

Data type: UNSIGNED_32

Index: 23938

d

= 5D82

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00640 | Resp. to pole pos. id. monit.

Data type: UNSIGNED_32

Index: 23935

d

= 5D7F

h

Error response for abort of the

pole position identification

Adjustment of the pole position identification

Selection list

(Lenze setting printed in bold)

1 Fault
4 Warning locked
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1