Parameter list | C00645

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00645

C00646

C00647

C00648

C00649

Parameter | Name:

C00645 | PLI 360° absolute current amplitude

Data type: UNSIGNED_32

Index: 23930

d

= 5D7A

h

From software version V2.0

Adjustment of the pole position identification

Display range

(min. value | unit | max. value)

0.00

A

1000.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00646 | PLI min.mov. curr. amplitude

Data type: UNSIGNED_32

Index: 23929

d

= 5D79

h

Percentage adjustment of the current amplitude for the

pole position identification

Stop!

If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,

the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

1

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00647 | PolePosId min.mov. cur.rise rate

Data type: UNSIGNED_32

Index: 23928

d

= 5D78

h

Percentage adjustment of the rate of current rise for the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

5

%

1000 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00648 | PolePosId min.mov. gain

Data type: UNSIGNED_32

Index: 23927

d

= 5D77

h

P component of the PI controller for the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

10.00 0.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00649 | PLI min. mov. reset time

Data type: UNSIGNED_32

Index: 23926

d

= 5D76

h

I component of the PI controller for the

pole position identification

Adjustment of the pole position identification

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

6000.00 62.50 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100