1 basic settings, Basic settings, 6motor interface – Lenze E94AxPExxxx User Manual

Page 212

Advertising
background image

6

Motor interface

6.5

Sensorless vector control (SLVC)

212

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.5.1

Basic settings

After the motor and controller have been optimally adjusted to each other, the "initial

commissioning steps" described in the following table are sufficient for a quick initial

commissioning.

• Detailed information on the individual steps can be found in the following subchapters.

Tip!
A precise adjustment of the motor parameters for an improved concentricity factor and

stability is described in the chapter "

Optimising motor parameters

".

( 214)

How to optimise the control behaviour and adjust it to the concrete application is described

in the chapter "

Optimising the control mode

".

( 220)

Parameterisable additional functions are described correspondingly in the chapter

"

Parameterisable additional functions

".

( 248)

Initial commissioning steps

1.

Parameterising speed and torque controller

.

( 213)

2. Additional "flying restart" function:

• In the Lenze setting, this parameterisable additional function is activated.

• If the flying restart function is not required, deactivate this function.

Flying restart function ( 257)

Only deactivate the flying restart if it is ensured that the drive is always at standstill in the case of controller

enable!

3. Additional "DC-injection braking" function:

• In the Lenze setting, this parameterisable additional function is deactivated.

• If DC-injection braking is required, activate this function.

DC-injection braking ( 260)