12 basic drive functions – Lenze E94AxPExxxx User Manual

Page 600

Advertising
background image

12

Basic drive functions

12.13

Cam data management

600

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.13.5

Invalid cam data due to changed machine parameters

If one or more machine parameters affecting the internal scaling of the cam data are changed, the

message "Cam Data: Invalidated due to change of mechanical data" (error number

0x00b80034

) is

entered into the logbook and the error response "Warning" occurs.

• The cam data are no longer valid and have to be recalculated.
• The warning is automatically reset if the

C00002

= "503: Calculate Cam Data" device command

is executed.

Calculate cam data

( 140)

Machine parameters affecting the internal scaling of the cam data:

Parameter

Info

C00006

Selection of the motor control

C00100

Resolution of an encoder revolution

C02520

/

C02521

Gearbox factor - motor (if motor = reference source)

C02522

/

C02523

Gearbox factor - position encoder (if position encoder = reference source)

C02524

Feed constant

C02570

Position control structure

Advertising