45 restart controller, 5drive interface – Lenze E94AxPExxxx User Manual
Page 145
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
145
5
Drive interface
5.2
Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.45
Restart controller
The
= "11000: Restart controller" device command is used to restart the controller via
parameter setting.
• Only possible when the application has stopped and the controller is inhibited.
Possible status displays for this device command
Status (
Meaning
720930050 Device command in process
720896001 General error
Note!
Due to the restart at the successful execution of the device command, this status is no
longer displayed in
.
If this device command is used, the message "Undervoltage in the DC bus (0x007b000f)"
may appear in the logbook.