2 selecting the required safety module, 3 system block "ls_safetymoduleinterface, Safety engineering – Lenze E94AxPExxxx User Manual

Page 408: System block is provided, 11 safety engineering

Advertising
background image

11

Safety engineering

11.2

Selecting the required safety module

408

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.2

Selecting the required safety module

The safety module expected by the application and the controller is selected in

C00214

.

• In »Engineer« this setting is carried out automatically by assigning the device modules to the

controller, i.e. »Engineer« automatically sets

C00214

according to the safety module selected.

• If the safety module selected in

C00214

does not correspond to the safety module type

connected, an error will be activated.

11.3

System block "LS_SafetyModuleInterface"

Outputs

Identifier

Data type

Value/meaning

SMI_dnState

DINT

Bit coded status information from the safety module

Status information ( 409)

SMI_dnIoState

DINT

Bit coded I/O status information from the safety module

I/O status information ( 410)

SMI_dwControl

DWORD

Bit coded control information from the safety module

Control information ( 410)

SMI_bPowerStageEnable

BOOL

Status signal "Inverter enable"

TRUE Inverter is enabled by the safety module.

SMI_byModuleId

BYTE

ID of the safety module available in the controller

SMI_dwControl

SMI_dnState

SMI_dnIoState

SMI_bPowerStageEnable

SMI_byModuleId