Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

99

5

Drive interface

5.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.6

Save start parameters

Controller parameter changes made via »Engineer« or keypad will get lost after mains switching of

the controller or loading of another application unless the settings have been explicitly saved.
With the device command

C00002

= "11: Save start parameters" the current parameter settings of

the active application can be saved with mains failure protection in the memory module of the

controller:

[5-16] "Save start parameters" function

Tip!
With the keypad this device command can be executed via the left function key if it is

currently assigned with the  function.

* In this example, application 1 is the active application

PS

9400

RAM

Firmware

Application 1*

PS

Application 3

PS

Application 2

PS

Memory module MM

PS

Application 1*

Note!

The saving process can take several seconds. Before you switch off the supply voltage

after having executed this device command, therefore be absolutely sure to check via

the status display in

C00003

whether the device command has been executed

successfully!
Saving of the cam data
This device command serves to save the Cam data safe against mains failure in the

memory module.

• The saving process is only carried out if the cam data in the controller and the memory

module differ from each other (based on the time stamp/GUID of the cam data).

• For saving the cam data, you do not need to enter a possibly existing user password

(

C02900

).

• The

C00002

= "502: Save Cam Data" device command remains available.

Save cam

data

( 138)