Mode 1021: ds402 homing method 21, 12 basic drive functions – Lenze E94AxPExxxx User Manual
Page 496
![background image](/manuals/566084/496/background.png)
12
Basic drive functions
12.6
Homing
496
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 1021: DS402 homing method 21
Procedures:
Case 1:
Axis has not yet activated the reference switch:
1. Movement in negative direction with profile data set 1.
2. Reversing with positive edge of the reference switch and change to profile data set 2.
3. The following negative edge of the reference switch sets the reference.
4. Absolute positioning to target position (
) with profile data set 2 (if
= "0").
Case 2:
Axis already stands on the reference switch:
1. Movement in positive direction with profile data set 2.
2. The following negative edge of the reference switch sets the reference.
3. Absolute positioning to target position (
) with profile data set 2 (if
= "0").
Reference switch
1
2
0