1 modes of operation, 2 signal configuration, Signal configuration ( 555) – Lenze E94AxPExxxx User Manual

Page 555: 12 basic drive functions

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

555

12

Basic drive functions

12.12

Brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.12.2.1 Modes of operation

Various operating modes are available in

C02580

for different applications and tasks:

Mode 0: Brake control is switched off

( 569)

Mode 1/11: Direct control of the brake

( 570)

• Without a specific logic or automatic system, can for instance be used to carry out a simple

check on whether the brake switches correctly.

Mode 2/12: Automatic control of the brake

( 571)

• The normal mode for the control of mech. holding brakes with and without holding torque

precontrol.

Mode 22: Automatic DC-injection braking

( 576)

• DC-injection braking for V/f control and sensorless vector control.

12.12.2.2 Signal configuration

The signal configuration of the control and status signals for the brake logic and monitoring

function is executed via the parameters shown in the following signal flows.

Direct brake control
This triggering of the holding brake does not need the motor brake control module:

[12-29] Direct control of the motor holding brake

C02583

: Status input monitoring

 Brake control via relay/contactor at digital output

 Feedback by "Brake function test"

1

0

M

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

GO

24O

DO1

DO2

DO3

DO4

?

bBrakeApplied

bReleaseBrake

bReleaseBrakeOut

1

0

Digital I/O

Digital I/O

Brake logic

Monitoring

Advertising