779

15

Parameter reference

15.2

Parameter list | C00181

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00181

C00182

C00183

C00185

Parameter | Name:

C00181 | Red. brake chopper threshold

Data type: UNSIGNED_32

Index: 24394

d

= 5F4A

h

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0

V

100 0 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00182 | Time for device search function

Data type: UNSIGNED_16

Index: 24393

d

= 5F49

h

From software version V3.0

Setting range

(min. value | unit | max. value)

Lenze setting

0

6000 5

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00183 | Device status

Data type: UNSIGNED_32

Index: 24392

d

= 5F48

h

Display of the device state for diagnostic purposes
Selection list

(read only)

0 Operation
1 Operation/Warning active
2 Operation/warning locked act.
3 Operation/Quick stop active
4 Operation/Application stopped

10 Initialisation active
20 System fault active
90 Device is switched on
91 Device is switched on/QSP trouble
95 Device switched-on/energy saving

mode

101 Safe torque off active
102 Fault active
104 Trouble is active
141 Drive ready to start --> C00142
151 Quick stop by trouble active

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00185 | Mains recov. detect. threshold

Data type: UNSIGNED_32

Index: 24390

d

= 5F46

h

This code must not be written to by the user!
Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 90 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising